Browse Categories

Search Results

AIR BAC-RSK25

Items #: AIR BAC-RSK25

Air BAC-RSK25 25FT inlet snorkel assembly, from outsid
Call For Availability
UOM : EA
$125.00


Add to Quote
Previous Purchase

AIR BAC-RSK50

Items #: AIR BAC-RSK50

REMOTE INLET SNORKEL ASSEMBLY - 50'
Call For Availability
UOM : EA
$195.00


Add to Quote
Previous Purchase

AIR BACB-196

Items #: AIR BACB-196

The COOL-BOX provides low cost cool air anywhere and can operate with any airline Type-C mask or hood style respirator. Ideal for cooling Level “A” chemical suits and air supplied hoods. Provides cool air for up to four workers. Attaches easily to any plant Grade-D air source and eliminates the need and expense of noisy vortex cooling tubes.
Call For Availability
UOM : EA
Call for Price


Add to Quote
Previous Purchase

AIR BB100-CO6

Items #: AIR BB100-CO6

It also has standard filter change indicators for for all 3 filtration stages. The Breather Box is a portable Grade-D filtration system designed to provide breathing air for a specific number of workers. The system filters incoming air from a compressor to provide respirator users with Grade-D quality air and monitors for CO. The first stage element filters bulk water and particulate and has an auto drain. The second stage coalescing filter eliminates atomized oils, mists, ultra-fine particulates, and has an auto drain. The third stage filter removes organic vapors and odors and has a manual drain. Filter change indicators are standard on all three stages of filtration. Filtration efficiency is 99.99% @ .01 micron. All Breather Boxes are designed to be used in the upright and closed position to prevent internal contamination. The standard carbon monoxide (CO) airline monitor operates on 8-16 volt DC, or 115 VAC for continuous air monitoring. An external audible alarm and light signals the workers of high CO content. Point-of-Attachment (POA) boxes can extend respirator usage beyond 300 feet. Features CO monitoring 100 cfm Breather Box - (123 cfm flow capacity) 6 couplings 99.99 percent filtration efficiency @ .01 micron External light & alarm signals Remote alarm jack Canadian Z180.1 BS-EN 12021:1999 OSHA 1910.134 Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Call For Availability
UOM : EA
$2,895.00


Add to Quote
Previous Purchase

AIR BB100-CO8

Items #: AIR BB100-CO8

Engineered for use in environments where the air quality is compromised. 3 stage air filtration system will remove up to 99.99 percent of airborne contaminants to 0.01 micron. The inline CO monitor detects carbon monoxide concentrations in parts per million.
Call For Availability
UOM : EA
$2,895.00


Add to Quote
Previous Purchase

AIR BB100-COAA

Items #: AIR BB100-COAA

Standard electric system features a reserve air trigger at 60 psig and / or loss of electrical power, it automatically switches to reserve air cylinder (or cylinders). Local & optional remote alarms will signal workers that their primary air system is in failure & has switched to a back up air supply system. If IDLH work environments exist, the Auto-Air Breather Box option should be considered. The Auto-Air filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs at 60 psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system Features 100 cfm Auto-Air Breather Box - (123 cfm flow capacity) - 4 couplings Filtration efficiency 99.99 percent @ 0.01 micron Fully Automatic Reserve Air System for Work in IDLH Environments Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder The primary air line connection is attached from the compressor to the Auto-Air Breather Box A reserve air line is attached from a single or bank of air cylinders based on the required egress duration and number of workers using the system The system can be tested prior to each use to ensure proper function of the Auto-Air system Always size the reserve air systems to allow an adequate safety factor for all workers to egress the environment Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Call For Availability
UOM : EA
$4,295.00


Add to Quote
Previous Purchase

AIR BB100-COIS

Items #: AIR BB100-COIS

The 1st stage element will filter bulk water & particulates, the 2nd stage coalescing filter will remove atomized oils & ultra-fine particulates & the 3rd stage will remove sorganic vapors & odors. A standard airline monitor operates with 9 Volt batteries & an audible alarm warns workers to high carbon monoxide concentrations. Features Intrinsically safe Flow capacity 123 CFM Filtration efficiency 99.99 percent @ 0.01 micron (Optional) Point of attachment boxes can extend respiratory usage to over 300 ft. 1/4 inch hansen or schrader type fittings Engineered to be used in closed & upright positions to prevent internal contamination 9 Volt batteries, 8 - 16 Volts DC or 115 Volts AC for continuous air monitoring External audible alarm & light OSHA 1910.134 compliant Size (L x H x D) - 26.5 X 21 X 9 inches
Call For Availability
UOM : EA
$2,795.00


Add to Quote
Previous Purchase

AIR BB100-COO2

Items #: AIR BB100-COO2

It also has standard filter change indicators for for all 3 filtration stages. The Breather Box is a portable Grade-D filtration system designed to provide breathing air for a specific number of workers. The system filters incoming air from a compressor to provide respirator users with Grade-D quality air and monitors for CO and O2. The first stage element filters bulk water and particulate and has an auto drain. The second stage coalescing filter eliminates atomized oils, mists, ultra-fine particulates, and has an auto drain. The third stage filter removes organic vapors and odors and has a manual drain. Filter change indicators are standard on all three stages of filtration. Filtration efficiency is 99.99% @ .01 micron. All Breather Boxes are designed to be used in the upright and closed position to prevent internal contamination. The standard carbon monoxide (CO) airline monitor operates on 8-16 volt DC, or 115 VAC for continuous air monitoring. An external audible alarm and light signals the workers of high CO content. Point-of-Attachment (POA) boxes can extend respirator usage beyond 300 feet. Features CO and O2 monitoring 100 cfm Breather Box - (123 cfm flow capacity) 4 couplings 99.99 percent filtration efficiency @ .01 micron External light & alarm signals Remote alarm jack Canadian Z180.1 BS-EN 12021:1999 OSHA 1910.134 Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Call For Availability
UOM : EA
$3,295.00


Add to Quote
Previous Purchase

AIR BB100-COPM

Items #: AIR BB100-COPM

The system filters compressor air to provide respirator users with Grade-D quality air. The first stage element filters bulk water and particulate, the second stage coalescing filter removes atomized oils and ultra-fine particulate, and the third stage removes organic vapors and odors. Filter change indicators are standard on all three filtration stages. Filtration efficiency is 99.99% @ .01 microns. A built-in carbon monoxide monitor operates on 115 VAC, or 8-16 VDC for continuous detection. A high intensity audible alarm and light signals the workers of high CO content in their breathing air. A 115 VAC electrical conduit box is provided as standard to provide AC power in and connection for AC powered remote alarms. Filtration components are mounted on powder coated steel panel. Features 100 CFM (123 CFM flow capacity) CO carbon monoxide monitor 99.99 percent filtration efficiency @ .01 microns 4 couplings or NPT outlet Integrated carbon monoxide (CO) monitor uses 115 Volts AC or 8 to 16 Volts DC for continuous detection Audible high intensity alarm & light will signal workers to high CO in breathing air supply All portable and fixed breathing air filtration systems meet or exceed OSHA 1910.134, Canadian Z180.1 Breathing Air Standards and British Standard BS-EN 12021:1999 “RESPIRATORY PROTECTIVE DEVICES” All filtration units are designed to flow the NIOSH maximum capacity per worker Air Systems provides at NO CHARGE your first lab certified air quality test of your new breathing air filtration device Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge.
Call For Availability
UOM : EA
$2,795.00


Add to Quote
Previous Purchase

AIR BB100-FK

Items #: AIR BB100-FK

FILTER KIT FOR BB100-CO & BB150-CO
Call For Availability
UOM : EA
$375.00


Add to Quote
Previous Purchase
  • « PREV
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • NEXT »