Search in Category
SCBA (Self Contained Breathing Apparatus)
Search term required.
Filter Your Search
Brand
Browse Categories
Loading...
SCBA (Self Contained Breathing Apparatus)
Viewing Page 5 of 65
(644 results)
AIR BB30-CO2R
Items #:
AIR BB30-CO2R
It also has standard filter change indicators for for all 3 filtration stages.
The Breather Box is a portable Grade-D filtration system designed to provide breathing air for a specific number of workers. The system filters incoming air from a compressor to provide respirator users with Grade-D quality air and monitors for CO.
The first stage element filters bulk water and particulate and has an auto drain. The second stage coalescing filter eliminates atomized oils, mists, ultra-fine particulates, and has an auto drain. The third stage filter removes organic vapors and odors and has a manual drain. Filter change indicators are standard on all three stages of filtration. Filtration efficiency is 99.99% @ .01 micron. All Breather Boxes are designed to be used in the upright and closed position to prevent internal contamination.
The standard carbon monoxide (CO) airline monitor operates on 8-16 volt DC, or 115 VAC for continuous air monitoring. An external audible alarm and light signals the workers of high CO content. Point-of-Attachment (POA) boxes can extend respirator usage beyond 300 feet.
Features
30 cfm Breather BoxTM - (48 cfm flow capacity)
2 couplings
2 independent regulators and pressure gauges
99.99 percent filtration efficiency @ .01 micron
9 Volt disposable batteries
External light & alarm signals
Remote alarm jack
Canadian Z180.1
BS-EN 12021:1999
OSHA 1910.134
Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
AIR BB30-CO3
Items #:
AIR BB30-CO3
It also has standard filter change indicators for for all 3 filtration stages.
The Breather Box is a portable Grade-D filtration system designed to provide breathing air for a specific number of workers. The system filters incoming air from a compressor to provide respirator users with Grade-D quality air and monitors for CO.
The first stage element filters bulk water and particulate and has an auto drain. The second stage coalescing filter eliminates atomized oils, mists, ultra-fine particulates, and has an auto drain. The third stage filter removes organic vapors and odors and has a manual drain. Filter change indicators are standard on all three stages of filtration. Filtration efficiency is 99.99% @ .01 micron. All Breather Boxes are designed to be used in the upright and closed position to prevent internal contamination.
The standard carbon monoxide (CO) airline monitor operates on 8-16 volt DC, or 115 VAC for continuous air monitoring. An external audible alarm and light signals the workers of high CO content. Point-of-Attachment (POA) boxes can extend respirator usage beyond 300 feet.
Features
CO monitoring
30 cfm Breather Box - (48 cfm flow capacity)
3 couplings
99.99 percent filtration efficiency @ .01 micron
External light & alarm signals
Remote alarm jack
Canadian Z180.1
BS-EN 12021:1999
OSHA 1910.134
Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
AIR BB30-COAA
Items #:
AIR BB30-COAA
Brand: Air Systems International
30 CFM AUTO-AIR BREATHER BOX "FILTRATION SYSTEM 115VAC, 3-FITTINGS"
AIR BB30-COAAP
Items #:
AIR BB30-COAAP
Pneumatic system features a reserve air trigger at 60 psig and / or loss of electrical power, it automatically switches to reserve air cylinder (or cylinders). Local & optional remote alarms will signal workers that their primary air system is in failure & has switched to a back up air supply system.
If IDLH work environments exist, the Auto-Air Breather Box option should be considered. The Auto-Air filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs at 60 psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system
Features
30 cfm Intrinsically Safe Auto-Air TM Breather BoxTM (48 cfm flow capacity) - 2 couplings
CSA approved Class I, Div. 1, groups D and C
Filtration efficiency 99.99 percent @ 0.01 micron
Fully Automatic Reserve Air System for Work in IDLH Environments
Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder
The primary air line connection is attached from the compressor to the Auto-Air Breather Box A reserve air line is attached from a single or bank of air cylinders based on the required egress duration and number of workers using the system
The system can be tested prior to each use to ensure proper function of the Auto-Air system
Always size the reserve air systems to allow an adequate safety factor for all workers to egress the environment
Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
AIR BB30-COO2
Items #:
AIR BB30-COO2
It also has standard filter change indicators for for all 3 filtration stages.
The Breather Box is a portable Grade-D filtration system designed to provide breathing air for a specific number of workers. The system filters incoming air from a compressor to provide respirator users with Grade-D quality air and monitors for CO and O2.
The first stage element filters bulk water and particulate and has an auto drain. The second stage coalescing filter eliminates atomized oils, mists, ultra-fine particulates, and has an auto drain. The third stage filter removes organic vapors and odors and has a manual drain. Filter change indicators are standard on all three stages of filtration. Filtration efficiency is 99.99% @ .01 micron. All Breather Boxes are designed to be used in the upright and closed position to prevent internal contamination.
The standard carbon monoxide (CO) airline monitor operates on 8-16 volt DC, or 115 VAC for continuous air monitoring. An external audible alarm and light signals the workers of high CO content. Point-of-Attachment (POA) boxes can extend respirator usage beyond 300 feet.
Features
CO and O2 monitoring
30 cfm Breather Box - (48 cfm flow capacity)
2 couplings
99.99 percent filtration efficiency @ .01 micron
External light & alarm signals
Remote alarm jack
Canadian Z180.1
BS-EN 12021:1999
OSHA 1910.134
Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
AIR BB30-COPM
Items #:
AIR BB30-COPM
Brand: Air Systems International
The Air Systems BB30-COPM is a Grade-D filtration system to supply breathing air for a specific amount of workers.
The BB30-COPM system filters the incoming air from your compressor to supply-respirators with Grade D quality air.
The 1st stage element will filter bulk water & particulate. The 2nd stage is a coalescing filter that eliminates ultra-fine particulates, mists & atomized oils. The 3rd stage filter will remove organic vapors & odors. The filter change indicator is standard for all 3 filtration stages. The efficiency of filtration is 99.99 percent at .01 micron.
A built in carbon monoxide (CO) monitor operates with 9 Volt DC, 115 Volt AC, or 8 to 16 VDC providing continuous detection. The audible high intensity alarm & light alerts workers to high carbon monoxide content in the breathing air supply. A 115 Volt AC conduit box (included) provides power in & connections for remote AC powered alarms. The filtration components come mounted on a powder-coated steel panel.
* When ordering, please specify .25 inch Hansen or Schrader style fittings
All fixed and portable breathing air filtration systems exceed or meet Breathing Air Standards
OSHA 1910.134
Canadian Z180.1
British BS-EN 12021:1999 Standard - RESPIRATORY PROTECTIVE DEVICES
All units designed to flow NIOSH max. capacity per worker
Air Systems will provide your 1st lab certified (at NO CHARGE) air quality test for your new filtration device
AIR BB30-HTAAP
Items #:
AIR BB30-HTAAP
Operates with 2400 - 5000 PSI cylinders and is suitable for hazardous locations.
Intrinsically Safe (IS) CO Monitors are CSA Approved for Class I, Division 1, Groups C and D Environments. Units are DC 9-Volt Operation Only
Features
30 cfm Intrinsically Safe Auto-Air Cart Small - (48 cfm flow capacity)
2 couplings
Please specify 1/4” Hansen style or Schrader style fittings when ordering
Other fittings available for an additional charge
Holds two 60 CF air cylinders
2 year warranty on sensor and monitor
Applications
Refineries
Chemical and Pharmaceutical manufacturing
Refueling applications
Tank cleaning
Decon required situations
Grain silo entry
All lights and remote alarms are pneumatically operated and spark free. The intrinsically safe CO monitor is CSA approved and operates on 9-volt DC batteries only.
AIR BB30COAAPM
Items #:
AIR BB30COAAPM
The system filters compressor air to provide respirator users with Grade-D quality air. The first stage element filters bulk water and particulate, the second stage coalescing filter removes atomized oils and ultra-fine particulate, and the third stage removes organic vapors and odors. Filter change indicators are standard on all three filtration stages. Filtration efficiency is 99.99% @ .01 microns. A built-in intrinsically safe carbon monoxide monitor operates on 115 VAC, or 8-16 VDC for continuous detection. A high intensity audible alarm and light signals the workers of high CO content in their breathing air. A 115 VAC electrical conduit box is provided as standard to provide AC power in and connection for AC powered remote alarms. Filtration components are mounted on powder coated steel panel.
Features
30 CFM Grade-D Auto-Air breathing air panel (48 CFM flow capacity)
CO carbon monoxide monitor
99.99 percent filtration efficiency @ .01 microns
4 couplings or NPT outlet
Integrated carbon monoxide (CO) monitor uses 115 Volts AC or 8 to 16 Volts DC for continuous detection
Audible high intensity alarm & light will signal workers to high CO in breathing air supply
All portable and fixed breathing air filtration systems meet or exceed OSHA 1910.134, Canadian Z180.1 Breathing Air Standards and British Standard BS-EN 12021:1999 “RESPIRATORY PROTECTIVE DEVICES”
All filtration units are designed to flow the NIOSH maximum capacity per worker
Air Systems provides at NO CHARGE your first lab certified air quality test of your new breathing air filtration device
Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge.
AIR BB30COPMIS
Items #:
AIR BB30COPMIS
The system filters compressor air to provide respirator users with Grade-D quality air. The first stage element filters bulk water and particulate, the second stage coalescing filter removes atomized oils and ultra-fine particulate, and the third stage removes organic vapors and odors. Filter change indicators are standard on all three filtration stages. Filtration efficiency is 99.99% @ .01 microns. A built-in intrinsically safe carbon monoxide monitor operates on 9-volt DC for continuous detection. A high intensity audible alarm and light signals the workers of high CO content in their breathing air. A 115 VAC electrical conduit box is provided as standard to provide AC power in and connection for AC powered remote alarms. Filtration components are mounted on powder coated steel panel.
Features
30 CFM (48 CFM flow capacity)
CSA Approved intrinsically safe CO carbon monoxide monitor
99.99 percent filtration efficiency @ .01 microns
2 couplings or NPT outlet
Integrated carbon monoxide (CO) monitor uses 9 Volts DC for continuous detection
Audible high intensity alarm & light will signal workers to high CO in breathing air supply
All portable and fixed breathing air filtration systems meet or exceed OSHA 1910.134, Canadian Z180.1 Breathing Air Standards and British Standard BS-EN 12021:1999 “RESPIRATORY PROTECTIVE DEVICES”
All filtration units are designed to flow the NIOSH maximum capacity per worker
Air Systems provides at NO CHARGE your first lab certified air quality test of your new breathing air filtration device
Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge.