Browse Categories
Simultaneous test set I
Draeger

Dräger HazMat Simultaneous Test Kit I

Brand: Draeger
PN: DRA 8101735
MPN: 8101735
Availability: Call For Availability
NIGP Code: 680.00000
UNSPSC Code: 41113100
FEMA AEL Category Code: 07CD-01-KCTC

Dräger-Tubes Simultaneous Test Set I Detects acid gases (e.g. hydrochloric acid, nitric acid), hydrocyanic acid, carbon monoxide, basic type gases (e.g. ammonia, butylamine) and nitrous gases (NO & NO2)

?The Dräger HazMat Simultest Kit is designed to quickly determine the presence of inorganic and organic gases and vapors. The Simultaneous Test Sets I, II & III consist of five tube sets to detect toxic substances generated from burning combustible materials, flammable liquids or flammable gases and substances evolving from a chemical leak or spill.

Short-term tubes and MicroTubes are designed for on-the-spot measurements at a particular location over a relatively short time period. Short-term tube measurements may last from 50 seconds to 15 minutes or so depending on the particular Dräger-Tube and sampling pump. Most measurements take less than 4 minutes. The MicroTubes address low range detection into the ppb levels.

High precision guaranteed: The Dräger sampling tubes and systems are very reliable in use even with complex compounds and mixtures of substances.

Dräger-Tubes are used in conjunction with either a manual or automatic sampling pump using individual Dräger-Tubes or special 5 tube sets for simultaneous measurement. Dräger Pumps and short-term Dräger-Tubes® are not interchangeable with other manufacturers’ pumps and detector tubes.

Dräger-Tubes Simultaneous Test Set I Detects acid gases (e.g. hydrochloric acid, nitric acid), hydrocyanic acid, carbon monoxide, basic type gases (e.g. ammonia, butylamine) and nitrous gases (NO & NO2)

Time savings of up to 50%
?The Dräger HazMat Simultaneous Test Sets are prepackaged sets of 5 tubes. Air is drawn through the 5 tubes simultaneously using the Dräger 5 tube manifold. The time to draw the air sample is less than 1 minute as compared to approximately 10 minutes using individual tubes.

Qualify gases and vapors for increased safety
?Sets I and II are dedicated to inorganic gases and Set III for organic vapors. Set III quickly identifies the presence of ketones, aromatics, alcohols, aliphatics and chlorinated hydrocarbons.

Reliable performance under tough conditions
The influence on measurement results by environmental factors like variable ambient temperature or high humidity are reduced to a minimum. This ensures reliable measurements under tough environmental conditions. The contents of the kit are securely packaged in a rugged Pelican case.

No calibration
?The tubes are calibrated at the factory and have a two year shelf life (storage between 41-77 °F). The Dräger accuro hand pump does not require calibration, just a simple leak test to confirm the pump will deliver the prescribed volume.

Easy to use
?The HazMat Simultest Kit is ready for immediate use in emergency response situations. The measurement procedure is the same for each set, minimizing training. Laminated full color instruction cards are supplied to provide a quick reference on the simple sampling procedures and accurate interpretation of results.